Products Description




Company Information | |||
[email protected] | |||
Mobile | +8613666033393 | ||
+8613666033393 | |||
13666033393 |
Technical Specifications
Parameter | Specification |
---|---|
Product Type | 3300 XL 8 mm Proximity Probe |
Thread Type | M10 x 1 |
Probe Tip Diameter | 8 mm (0.31 in) |
Case Material | AISI 303 or 304 stainless steel |
Probe Tip Material | Polyphenylene Sulfide (PPS) |
Cable Type | 75 Ω triaxial, FEP insulated |
Connector Type | Miniature ClickLoc, gold-plated |
Total Length | 1.0 meter |
Weight | Approx. 0.323 kg |
Nominal DC Resistance (RPROBE) | 7.59 ± 0.50 Ω |
Linear Range | 0.25 mm to 2.3 mm (10 to 90 mils) |
Recommended Gap Setting | 1.27 mm (50 mils) at -9 Vdc |
Incremental Scale Factor (ISF) | 7.87 V/mm (200 mV/mil) ± 5% |
DSL Accuracy | ±0.025 mm (±1 mil) |
Frequency Response | 0 to 10 kHz, +0/-3 dB (with up to 305 m cable) |
Minimum Target Diameter | 15.2 mm (0.6 in) |
Recommended Shaft Diameter | ≥ 76.2 mm (3 in) |
Operating Temperature Range | -52°C to +177°C |
Storage Temperature Range | -52°C to +177°C |
Humidity Resistance | ≤ 3% ASF change in 93% RH, 56 days (IEC 68-2-3) |
Pressure Resistance | Viton® O-ring seal, not pressure-tested by default |
Minimum Cable Bend Radius | 25.4 mm (1.0 in) |
Environmental Protection | Connector protectors recommended |
Approvals | CSA, ATEX, IECEx compliant (option 05) |
FAQ
Frequently Asked Questions (FAQ)
Q1: What is the function of the 330103-00-10-10-02-05 proximity probe?
A1: It measures both static (position) and dynamic (vibration) displacements of rotating machinery by detecting the distance between the probe tip and a conductive surface.
Q2: What materials are used in the probe’s construction?
A2: The probe tip is molded with PPS (Polyphenylene Sulfide) and the probe case is constructed from AISI 303 or 304 stainless steel for durability and corrosion resistance.
Q3: Is this proximity probe compliant with API 670 standards?
A3: Yes, the standard 3300 XL 8 mm system complies with API 670 standards in terms of mechanical design, linearity, and temperature stability.
Q4: What is the significance of the ClickLoc connector?
A4: ClickLoc connectors are gold-plated and feature a locking mechanism that provides reliable, finger-tight connections without the need for special tools.
Q5: Can this probe be used in high-temperature applications?
A5: The standard version supports up to +177°C. For temperatures up to +218°C (probe tip) and +260°C (cable), an Extended Temperature Range (ETR) version is available.
Q6: How is the probe installed and mounted?
A6: The probe features an M10 x 1 threaded body for secure mounting and is typically installed using corresponding brackets or mounts, ensuring proper gap alignment.
Q7: What is the recommended gap voltage setting for radial vibration measurements?
A7: The recommended gap setting is -9 Vdc, which corresponds to a distance of approximately 1.27 mm (50 mils).
Q8: Is field calibration required when replacing components?
A8: No. All components in the 3300 XL system are fully interchangeable and factory calibrated to AISI 4140 steel, eliminating the need for field calibration.
Tags
Packing & Delivery
We will use wear-resistant cartons to seal the boxes, and take photos for your confirmation before sealing. We will pack the boxes only after confirmation.
For express delivery, we will use DHL, UPS, TNT, FedEx and EMS.
Please rest assured that we have a deep cooperation with express delivery companies and can ensure that your goods are delivered to you in good condition.