Technical Specifications
Parameter | Value |
---|---|
Cable Length | 4.5 meters |
Weight | 0.153 kg |
Extension Cable DC Resistance (RCORE) | 0.99 Ω ± 0.15 (for 4.5 meters) |
Resistance (RJACKET) | 0.30 Ω ± 0.06 (for 4.5 meters) |
Capacitance | 69.9 pF/m (21.3 pF/ft) |
Field Wiring | 0.2 to 1.5 mm² (16 to 24 AWG) |
Minimum Cable Bend Radius | 25.4 mm (1.0 in) |
Maximum Connector Torque | 0.565 N•m (5 in•lbf) |
Temperature Range | Operating: -52°C to +177°C (-62°F to +350°F) |
Frequency Response | (0 to 10 kHz), +0, -3 dB with up to 305 meters (1000 feet) of field wiring |
Linear Range | 0.25 mm to 2.3 mm (10 to 90 mils) |
Minimum Target Size | 15.2 mm (0.6 in) diameter |
Shaft Diameter (Minimum) | 50.8 mm (2 in) |
FAQ
FAQ
-
What is the length of the Bently Nevada 3300 XL extension cable?
-
The Bently Nevada 3300 XL extension cable has a length of 4.5 meters.
-
-
What is the weight of the Bently Nevada 3300 XL extension cable?
-
The weight of the cable is 0.153 kg.
-
-
What is the minimum bending radius for the Bently Nevada 3300 XL extension cable?
-
The minimum bending radius is 25.4 mm (1.0 in).
-
-
What is the recommended field wiring for the extension cable?
-
The recommended field wiring is between 0.2 to 1.5 mm² (16 to 24 AWG), and it is advised to use a 3-conductor shielded triad cable with tinned field wiring.
-
-
What is the frequency response of the Bently Nevada 3300 XL extension cable?
-
The frequency response is from 0 to 10 kHz, with a ±3 dB roll-off, and can support up to 305 meters (1000 feet) of field wiring.
-
-
What is the maximum torque for the cable’s connectors?
-
The maximum connector torque is 0.565 N•m (5 in•lbf).
-
-
What is the operating temperature range for the extension cable?
-
The operating temperature range is between -52°C to +177°C (-62°F to +350°F).
-
-
What is the linear range of the Bently Nevada 3300 XL extension cable system?
-
The linear range is from 0.25 mm to 2.3 mm (10 to 90 mils), with a gap setting at -9 Vdc (approximately 1.27 mm or 50 mils).
-