Products Description




Company Information | |||
[email protected] | |||
Mobile | +8613666033393 | ||
+8613666033393 | |||
13666033393 | |||
Add | Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China |
Technical Specifications
Parameter | Value |
---|---|
Product Type | Discrete Output Module |
Discrete Output Number | 16 outputs |
Groups of Channels | 4 groups of 4 channels |
Supply Frequency | 47…63 Hz |
Maximum Voltage Drop | 1.5 V |
Discrete Output Voltage | 83…253 V AC |
Addressing Requirement | 1 output word |
Absolute Maximum Output | 300 Vrms 10 s AC |
400 Vrms 1 cycle AC | |
Maximum Load Current | 2 mA rms 115 Vrms (off state leakage per output) |
2.5 mA rms 230 Vrms (off state leakage per output) | |
3 A rms 170…253 V (per output) | |
4 A rms 85…132 V (per output) | |
16 A rms per module | |
4 A rms per group | |
Surge Current | 10 A during 3 cycles per point |
20 A during 2 cycles per point | |
30 A during 1 cycle per point | |
25 A during 3 cycles per group | |
30 A during 2 cycles per group | |
45 A during 1 cycle per group | |
DV/dt | 400 V/ms |
Response Time | <= 0.5 ms at state 0 to state 1 |
<= 0.5 ms at state 1 to state 0 | |
Fault Indication | Blown fuse |
Loss of field power | |
Protection Type | Internal by RC filter |
Internal output protection by 5 A fuse | |
Power Dissipation | 1.85 + (1.1 V x total module load current) |
Marking | CE |
Local Signalling | for bus communication: 1 LED (green) |
for external fault detected (F): 1 LED (red) | |
for input status: 16 LEDs (green) | |
Bus Current Requirement | 350 mA |
Module Format | Standard |
Net Weight | 0.45 kg (0.99 lb) |
Dimensions | 103.9 × 40.3 × 250 mm |
Environmental Conditions | Product Certifications: cUL, FM Class 1 Division 2 |
Standards: UL 508, CSA C22.2 No 142 | |
Electromagnetic Compatibility: | |
Electrostatic discharge immunity test: 4 kV (contact discharge) | |
Electrostatic discharge immunity test: 8 kV (air discharge) | |
Susceptibility to electromagnetic fields: 10 V/m (80…1000 MHz) | |
Ambient Air Temperature for Operation: 0…60 °C (32…140 °F) | |
Ambient Air Temperature for Storage: -40…85 °C (-40…185 °F) | |
Relative Humidity: 95% without condensation | |
Operating Altitude: <= 5000 m (16404.2 ft) |
FAQ
FAQ
Q1: What is the number of outputs provided by the Schneider 140DAO84210 module?
A1: The Schneider 140DAO84210 module provides 16 discrete outputs.
Q2: What is the maximum surge current supported by each output point?
A2: Each output point can support a maximum surge current of 30 A during 1 cycle.
Q3: What is the response time of the Schneider 140DAO84210 module when switching between states?
A3: The response time is less than or equal to 0.5 ms when switching from state 0 to state 1, and from state 1 to state 0.
Q4: How is the Schneider 140DAO84210 module protected from faults?
A4: It has protection from faults via an internal RC filter and a 5 A fuse for output protection.
Q5: What are the environmental conditions for the Schneider 140DAO84210 module’s operation?
A5: The module operates within a temperature range of 0…60 °C (32…140 °F) and can be stored between -40…85 °C (-40…185 °F).
Q6: What certifications and standards does the Schneider 140DAO84210 module meet?
A6: It is certified with cUL, FM Class 1 Division 2, and conforms to UL 508 and CSA C22.2 No 142 standards.
Q7: What is the module’s weight and dimensions?
A7: The Schneider 140DAO84210 module weighs 0.45 kg (0.99 lb) and has dimensions of 103.9 × 40.3 × 250 mm.
Q8: How is the bus current requirement for the Schneider 140DAO84210 module specified?
A8: The module requires a bus current of 350 mA.
Tags
Packing & Delivery
We will use wear-resistant cartons to seal the boxes, and take photos for your confirmation before sealing. We will pack the boxes only after confirmation.
For express delivery, we will use DHL, UPS, TNT, FedEx and EMS.
Please rest assured that we have a deep cooperation with express delivery companies and can ensure that your goods are delivered to you in good condition.