Products Description




Company Information | |||
[email protected] | |||
Mobile | +8613666033393 | ||
+8613666033393 | |||
13666033393 | |||
Add | Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China |
Technical Specifications
Parameter | Value |
---|---|
Product Range | Modicon Quantum Automation Platform |
Type | DC Discrete Output Module |
Number of Outputs | 32 |
Channel Grouping | 4 groups of 8 |
Output Logic Type | Positive logic (sourcing) |
Addressing Requirement | 2 output words |
Nominal Output Voltage | 24 V DC |
Output Voltage Range | 19.2…30 V DC |
Absolute Max Output Voltage | 50 V, 1-second decaying pulse |
Max Voltage Drop | < 0.4 V @ 0.5 A |
Max Load Current (Module) | 16 A |
Max Load Current (Group) | 4 A |
Surge Current | 2 A |
Response Time (1 to 0) | ≤ 0.1 ms |
Response Time (0 to 1) | ≤ 1 ms |
Max Leakage Current | 1 mA @ 24 V |
Load Inductance | L = 0.5 / (I² × f) H |
Fault Indication | Loss of field power, blown fuse |
Fuse Rating (per point) | 3 A |
Fuse Rating (per group) | 5 A |
Isolation (Channel to Bus) | 1780 Vrms DC for 1 min |
Isolation (Group to Group) | 500 Vrms DC for 1 min |
Protection Type | Internal fuse protection (5 A per group) |
Power Dissipation | 5 W |
Marking | CE |
Local Signaling | Green LED (bus active), Red LED (fault), 32 Green LEDs (status) |
Bus Current Requirement | 330 mA |
Module Format | Standard |
Dimensions (W × H × D) | 103.9 × 40.3 × 250 mm |
Weight | 0.45 kg (0.99 lb) |
Certifications and Environmental Specifications
Parameter | Value |
---|---|
Certifications | FM Class 1 Div 2, C-tick, RMRS, GOST |
Standards | CSA C22.2 No 142, UL 508 |
ESD Immunity | 4 kV contact, 8 kV air (IEC 801-2) |
EMI Immunity | 9.1 V/m (80–2000 MHz, IEC 801-3) |
Operating Temperature | 0–60 °C (32–140 °F) |
Storage Temperature | -40–85 °C (-40–185 °F) |
Relative Humidity | 95% non-condensing |
Operating Altitude | ≤ 5000 m (16404.2 ft) |
FAQ
Frequently Asked Questions (FAQ)
Q1: What type of output does the 140DDO35301 module support?
A1: It supports positive logic (sourcing) with 24 V DC output.
Q2: Are fuses required for each output point?
A2: Yes, each output point should be fused at 3 A, with a 5 A fuse per group.
Q3: What is the maximum current capacity of the module?
A3: The module supports up to 16 A total, with a maximum of 4 A per group.
Q4: Does the module provide fault indication for blown fuses?
A4: Yes, it includes a red LED for external faults such as blown fuses or field power loss.
Q5: What are the output response times?
A5: Response from 1 to 0 is ≤ 0.1 ms; from 0 to 1 is ≤ 1 ms.
Q6: Is there electrical isolation between channels and the bus?
A6: Yes, it offers 1780 Vrms DC isolation for 1 minute between channels and bus.
Q7: In what environments is the module certified to operate?
A7: The module is certified under FM, C-tick, RMRS, and GOST, suitable for industrial use.
Q8: How much power does the module consume during operation?
A8: It consumes 5 watts of power.
Tags
Packing & Delivery
We will use wear-resistant cartons to seal the boxes, and take photos for your confirmation before sealing. We will pack the boxes only after confirmation.
For express delivery, we will use DHL, UPS, TNT, FedEx and EMS.
Please rest assured that we have a deep cooperation with express delivery companies and can ensure that your goods are delivered to you in good condition.