Technical Specifications
Parameter | Description |
---|---|
Module Type | Universal Digital Input Slave Module |
Model | IMDSI12 |
Number of Input Channels | 16 |
Input Voltage Options | 24 VDC, 48 VDC, 125 VDC, 120 VAC |
Debounce Filter | Fixed 17 milliseconds |
Input Isolation | 1500 VDC between channels and logic circuitry |
Input Current (typical) | 5.5 mA (24 VDC), 4.7 mA (48 VDC), 4.5 mA (125 VDC), 4.8 mA (120 VAC) |
Turn-on Voltage (min) | 16.8 VDC (24 VDC), 20.1 VDC (48 VDC), 69.3 VDC (125 VDC), 54 VAC (120 VAC) |
Turn-off Voltage (max) | 13 VDC, 29 VDC, 58 VDC, 48 VAC (corresponding to input type) |
Leakage Current (max) | ≤10 µA |
Communication Interface | I/O Expander Bus to control module (passive contact interface) |
Power Consumption | 95 mA @ 5 VDC typical, 115 mA max |
Mounting | Occupies one slot in INFI 90 OPEN module mounting unit |
Environmental Temperature Range | 0°C to 70°C |
Humidity | 5% to 95% RH (non-condensing, up to 55°C) |
Altitude | 0 to 3000 meters above sea level |
Compliance | IEC 1010-1, IEC 255, IEC 68-2-1/2/3/14, CE, CSA, FM (Class I, Div. 2) |
Dimensions (W x H x D) | 132 x 25 x 125 mm |
Weight | 0.191 kg |
FAQ
Frequently Asked Questions (FAQ)
Q1: How many input channels does the IMDSI12 module provide?
A1: It provides 16 digital input channels.
Q2: What types of input voltage are supported?
A2: It supports 24 VDC, 48 VDC, 125 VDC, and 120 VAC.
Q3: Is the debounce filter time adjustable?
A3: No, the debounce filter is fixed at 17 milliseconds.
Q4: Does the module provide input isolation?
A4: Yes, it offers 1500 VDC isolation between channels and control logic.
Q5: What kind of mounting does the IMDSI12 require?
A5: It installs in one slot of a standard INFI 90 OPEN module mounting unit.
Q6: Can the IMDSI12 replace older IMDSI02 modules?
A6: Yes, it can replace the IMDSI02 with the correct jumper settings.
Q7: What is the module’s communication method with the controller?
A7: It uses the I/O Expander Bus for communication with the control module.
Q8: What is the typical operating environment?
A8: The module operates from 0°C to 70°C, 5% to 95% RH, non-condensing.