Technical Specifications
Item | Specification |
---|---|
Model | AAR145-S50 |
Number of Input Channels | 16 isolated channels |
Input Signal Types | RTD: Pt100 (JIS C1604:1997, IEC751:1995) POT: Total resistance 100 Ω–10 kΩ, span ≥ 50% of total |
Signal Selection | Each channel individually selectable as RTD or POT |
Allowable Input Voltage | ±5 V |
Isolation Voltage | Input to system: 500 V AC (1500 V AC for single card), Channel to channel: 200 V AC (1 min) |
Input Resistance (ON/OFF) | ≥ 1 MΩ |
Measurement Current (RTD) | 1 mA |
Accuracy | RTD: ±150 mΩ POT: ±0.2 %/FS |
Data Update Period | 1 second |
Temperature Drift | RTD: ±0.3 Ω/10 °C POT: ±0.4 %/10 °C |
Max Wiring Resistance | RTD: 150 Ω per wire |
Max Current Consumption | 350 mA (5 V DC) |
External Connection | Dedicated cable (KS8 or AKB335) |
Dimensions (W x H x D) | 130 x 127.2 x 32.8 mm |
Weight | 0.3 kg |
FAQ
Frequently Asked Questions (FAQ)
Q1: What RTD sensors are supported by the AAR145-S50?
A1: The module supports 3-wire Pt100 RTDs conforming to JIS C1604:1997 and IEC751:1995.
Q2: Can RTD and POT inputs be mixed?
A2: Yes. Each input channel can be independently configured for either RTD or POT.
Q3: What is the allowable resistance range for POT inputs?
A3: POTs must have total resistance between 100 Ω and 10 kΩ, with a span of at least 50% of the total resistance.
Q4: Is input isolation provided between channels?
A4: Yes. Channels are isolated from each other and from the system.
Q5: Does the AAR145 support thermocouple inputs?
A5: No. It only supports RTD and POT. For thermocouples, use models like AAT145.
Q6: Which control systems is this module compatible with?
A6: Compatible with control systems such as AFV30, AFV40, AFV10, and AFF50.
Q7: What is the maximum wiring resistance allowed for RTD inputs?
A7: The wiring resistance must not exceed 150 Ω per wire, and resistances for INA and INC must be equal.
Q8: What is the data update period of the AAR145?
A8: The module updates data every second (1-second update cycle).