Technical Specifications
Parameter | Details |
---|---|
Module Type | Analog Output Module (8 channels) |
Output Signal Range | 0–20 mA, 4–20 mA, 0–10 V, 2–10 V |
Number of Channels | 8 analog outputs, 8 disturbance outputs |
Resolution | 0.05% (quantization error) |
Total Error (R1010) | Max. ±0.9% |
Total Error (R1110) | Max. ±0.5% |
Linearity Error | Max. ±0.4% |
Temp Drift (0~70°C) | Max. ±0.1% |
Supply Voltage Range | 19.5…30 V DC |
Nominal Voltage | 24 V DC |
Current Consumption | 140 mA (typical) |
Power Dissipation | 5 W (unloaded) |
Voltage Output Load | ≥ 330 Ω |
Current Output Load | ≤ 500 Ω (≤ 330 Ω for >100% range) |
Fault Output Drive | ≥ 24 mA (30 mA typ.), short-circuit-proof |
Status Indication | Red LED on front for fault indication |
Interface | SEA standard interface to IO-Bus |
Address Setting | Via S1–S3 rotary switches (hex), 8 steps |
Processing Time | < 50 ms for all outputs |
Dimensions | 198 x 261 x 20 mm |
Weight | 0.55 kg |
Operating Temp | 0°C to +70°C |
Storage Temp | -40°C to +85°C |
FAQ
Frequently Asked Questions (FAQ)
Q1: What output ranges does the 81AA10E support?
A1: It supports 0–20 mA, 4–20 mA, 0–10 V, and 2–10 V signal ranges.
Q2: Is short-circuit protection available for outputs?
A2: Yes, all analog outputs are short-circuit-proof.
Q3: How many channels does the module have?
A3: The module provides 8 analog output channels and 8 associated disturbance outputs.
Q4: How is the module address configured?
A4: Address is configured via S1, S2, and S3 rotary switches on the front panel in hexadecimal steps.
Q5: What communication interface is used?
A5: The module uses the SEA standard interface to communicate over the IO-Bus system.
Q6: How are disturbances indicated?
A6: Disturbances are indicated via red LED, binary outputs ST1–ST8, and the SME line on the IO-Bus.
Q7: Can each output be configured as voltage or current?
A7: Yes, via configuration switches S6/S7 for each function unit.
Q8: What is the processing time for outputs?
A8: The processing time for all analog outputs is less than 50 milliseconds.