PR6423/010-010 Eddy Current Sensor
Parameter | Specification |
---|---|
Sensor Head Diameter | 8 mm |
Weight (Sensor with 1m Cable) | 0.1 kg (100 grams) |
Linear Measurement Range | 2 mm (80 mils) |
Initial Air Gap | 0.5 mm (20 mils) |
ISF (Incremental Scale Factor) | 8 V/mm ±5% @ 0–45°C |
DSL (Linearity Error) | ±0.025 mm (±1 mil) @ 0–45°C |
Minimum Shaft Diameter | 25 mm |
Target Material | Ferromagnetic Steel (42CrMo4 / AISI 4140 standard) |
Protection Class | IP66 (IEC 60529) |
Operating Temperature | Sensor + 1m Cable: -35 to +180°C; Cable & Connector: -35 to +150°C |
Materials | Tip: PEEK; Case: Stainless Steel; Cable: PTFE; Connector: Brass (nickel-plated) |
Thread Options | M10x1 or 3/8”-24 UNF |
Certification | CE, ATEX, IECEx, CSA, UL compliant |
CON021 Signal Converter
Parameter | Specification |
---|---|
Compatible Sensors | PR6422, PR6423, PR6424, PR6425, PR6426 |
Measuring Range (PR6423) | 2 mm (standard), 3–4 mm (extended range) |
Frequency Range | 0–20000 Hz |
Rise Time | <15 µs |
Power Supply Voltage | -23V to -32V (for output range -4V to -20V); -21V to -32V (for -2V to -18V) |
Operating Temperature | -30°C to +100°C |
Shock Resistance | 5g @ 60 Hz |
Protection Class | IP20 |
Housing Material | LMgSi 0.5 F22 |
Weight | ~0.12 kg (120 grams) |
Mounting | 4 x M5x20 screws |
Hazardous Area Certification | ATEX, IECEx, CSA (Intrinsic Safety and Non-sparking) |
FAQ
Frequently Asked Questions (FAQ)
Q1: What is the primary function of the PR6423/010-010 sensor?
A1: It is designed to measure shaft displacement, position, eccentricity, and speed in rotating machinery.
Q2: What is the diameter and weight of the sensor head?
A2: The sensor head diameter is 8 mm and weighs approximately 0.1 kg with a 1-meter cable.
Q3: Is the sensor suitable for use in hazardous areas?
A3: Yes, it is certified for use in hazardous environments according to ATEX, IECEx, and CSA standards.
Q4: What is the linear range of the sensor?
A4: The linear measurement range is 2 mm with a typical initial air gap of 0.5 mm.
Q5: What shaft material is required for accurate measurements?
A5: The target should be made of ferromagnetic steel, such as 42CrMo4 (AISI 4140).
Q6: Can the CON021 converter be used with other sensors?
A6: Yes, it supports PR6422, PR6423, PR6424, PR6425, and PR6426 series.
Q7: What is the output voltage range of the CON021 converter?
A7: It operates with an output range of -4V to -20V or -2V to -18V depending on supply voltage.
Q8: What is the protection level of the converter housing?
A8: The CON021 converter housing is rated IP20 and should be installed in a protected enclosure.