Technical Specifications
Item | Specification |
---|---|
Model | AO890 |
Article Number | 3BSC690072R1 |
Module Type | Analog Output |
Channels | 8 channels |
Signal Type | Unipolar, single-ended |
Signal Range | 0…20 mA / 4…20 mA |
Resolution | 12 bit |
Channel Isolation | Groupwise from ground |
Intrinsic Safety | Yes (built-in for each channel) |
Current Limiting | Yes, short-circuit protected, max 22 mA |
Accuracy | Typ. 0.05%, Max. 0.1% @ 650 Ω load |
Temperature Drift | Typ. 50 ppm/°C, Max. 100 ppm/°C |
Rise Time | 1 ms (10% to 90%) |
Load Resistance | <725 Ω at 20 mA, <625 Ω at 22 mA |
Rated Insulation Voltage | 50 V |
Dielectric Strength | 500 V AC |
Power Dissipation | 3.1 W |
Current Consumption +5V | 80 mA |
Current Consumption +24V Modulebus | Typ. 110 mA, Max. <150 mA |
Current Consumption +24V External | Typ. 220 mA, Max. <300 mA |
Supported MTUs | TU890 (Ex) and TU891 (non-Ex) |
HART Support | No |
SOE | No |
Redundancy | No |
High Integrity Mode | No |
Diagnostic LEDs | F (Fault), R (Run), W (Warning), O (Setpoint) |
Diagnostics | Internal power monitor, Open wire detection (>1 mA) |
Operating Temperature | 0 to +55°C |
Storage Temperature | -40 to +70°C |
Max Ambient Temperature | 55°C, or 40°C for vertical compact MTU |
Relative Humidity | 5% to 95%, non-condensing |
Protection Rating | IP20 (IEC 60529) |
Safety Compliance | EN 61010-1, EN 61010-2-201 |
EMC | EN 61000-6-2, EN 61000-6-4 |
Marine Certifications | ABS, BV, DNV, LR |
Dimensions (W x D x H) | 45 x 102 x 119 mm |
Weight | 0.2 kg |
FAQ
Frequently Asked Questions (FAQ)
Q1: Does the AO890 module support intrinsic safety?
A1: Yes, each channel includes intrinsic safety components for hazardous areas.
Q2: What is the maximum output current per channel?
A2: Normal range is 0–20 mA, with 22 mA maximum in overload.
Q3: Is HART communication supported?
A3: No, AO890 does not support HART communication.
Q4: Which MTU units are compatible with AO890?
A4: It is compatible with TU890 (for Ex applications) and TU891 (non-Ex).
Q5: Does AO890 support redundancy?
A5: No, redundancy is not supported in this module.
Q6: Are the output channels isolated from each other?
A6: No, channels are groupwise isolated from ground, not individually.
Q7: What is the load resistance range for AO890?
A7: Maximum 725 Ω at 20 mA and 625 Ω at 22 mA.
Q8: What hazardous area certifications are supported?
A8: Supports ATEX/IECEx Zone 2 to Zone 0 interface and cFMus C1 Div 2.