Technical Specifications
Parameter | Specification |
---|---|
Probe Model | 330103-00-05-50-02-00 |
Probe Tip Diameter | 8 mm (0.31 in) |
Thread Size | M10 x 1 |
Cable Type | Standard ClickLoc connector with standard cable |
Total Probe Length | 5.0 meters (16.4 ft) |
Weight (Total System) | 1.62 kg (5.0 m system) |
Probe Weight | 323 g/m (11.4 oz) |
Cable Weight | 34 g/m (0.4 oz/ft) |
Sensor Weight | 246 g (8.67 oz) |
Linear Range | 2 mm (80 mils) |
Recommended Gap Setting | 1.27 mm (50 mils), corresponding to -9 Vdc |
Incremental Scale Factor (ISF) | 7.87 V/mm (200 mV/mil) ±5% (5 m system) |
Deviation from Straight Line (DSL) | ±0.025 mm (±1 mil) for 5 m system |
Operating Temperature – Probe | -52°C to +177°C |
Operating Temperature – Cable | -52°C to +177°C |
Operating Temperature – Sensor | -52°C to +100°C |
Storage Temperature – Sensor | -52°C to +105°C |
Humidity Resistance | < 3% change in scale factor under 93% RH, 56 days |
Frequency Response | 0 to 10 kHz, +0 / -3 dB with up to 305 m wiring |
Output Resistance | 50 Ω |
Power Supply Requirement | -17.5 to -26 VDC, 12 mA max |
Pressure Seal | Viton® O-ring sealed; not pressure-tested by default |
Cable Bend Radius (Min.) | 25.4 mm (1 in) |
Armor (optional) | AISI 302 or 304 SST with FEP outer jacket |
FAQ
Frequently Asked Questions (FAQ)
Q1: What is the primary application of the 330103-00-05-50-02-00 probe?
A1: It is used for vibration and position monitoring in fluid-film bearing machines and for Keyphasor reference/speed measurements.
Q2: Does this probe meet API 670 standards?
A2: Yes, the 5-meter 3300 XL 8 mm system is fully compliant with API 670.
Q3: Can the probe and extension cable be mixed with other XL or non-XL components?
A3: They are backward compatible with non-XL 3300 5 mm and 8 mm components but doing so limits system performance.
Q4: What is the material of the probe case?
A4: The case is made of AISI 303 or 304 stainless steel.
Q5: What happens if I exceed the thread engagement limit?
A5: Exceeding thread length may cause installation binding. Warranty doesn’t cover thread damage from over-engagement.
Q6: Is special tooling required to install the connectors?
A6: No, the ClickLoc connectors only require finger-tightening. No tools are needed.
Q7: What is the output voltage range?
A7: Approximately -1 to -17 Vdc over the linear range (0.25 to 2.3 mm from the target).
Q8: How is resistance affected by probe length?
A8: Resistance increases with length; for 5 m, it is 8.73 ± 0.50 ohms (center to outer conductor).
Tags
Packing & Delivery
We will use wear-resistant cartons to seal the boxes, and take photos for your confirmation before sealing. We will pack the boxes only after confirmation.
For express delivery, we will use DHL, UPS, TNT, FedEx and EMS.
Please rest assured that we have a deep cooperation with express delivery companies and can ensure that your goods are delivered to you in good condition.