Technical Specifications
Parameter | Specification |
---|---|
Product Model | 330101-00-11-10-02-CN |
Probe Type | 3300 XL 8 mm Proximity Probe |
Application | Vibration and position measurements on fluid-film bearing machines |
Linear Range | 2.0 mm (80 mils), from 0.25 mm to 2.3 mm |
Recommended Gap | -9 VDC (~1.27 mm or 50 mils) |
Scale Factor | 7.87 V/mm (200 mV/mil) ± 5% (1 m/5 m system), ±6.5% (9 m system) |
Deviation from Straight Line | ±0.025 mm (1 mil) (1 m/5 m), ±0.038 mm (1.5 mil) (9 m) |
Frequency Response | 0 to 10 kHz, +0/-3 dB |
Operating Temperature (Probe) | -52°C to +177°C (standard), up to +218°C (ETR probe tip) |
Storage Temperature (Probe) | Same as operating |
Pressure Sealing | Viton® O-ring |
Minimum Target Diameter | 15.2 mm (0.6 in) |
Minimum Shaft Diameter | 50.8 mm (2 in); Recommended ≥ 76.2 mm (3 in) |
Probe Tip Material | Polyphenylene sulfide (PPS) |
Probe Case Material | AISI 303 or 304 stainless steel |
Cable Type | 75Ω triaxial, FEP insulated (standard), PFA insulated (ETR) |
Connector Type | Miniature coaxial ClickLoc with gold plating |
Minimum Cable Bend Radius | 25.4 mm (1.0 in) |
Thread Size | 3/8-24 UNF |
Total Length | 1.0 meter |
Weight | 0.323 kg |
FAQ
Frequently Asked Questions (FAQ)
Q1: What is the primary application of the 330101-00-11-10-02-CN proximity probe?
A1: It is primarily used for measuring vibration and shaft position in rotating machinery with fluid-film bearings.
Q2: Does this probe support high-temperature environments?
A2: Yes, the standard probe supports up to 177°C, and the ETR version can handle up to 218°C at the probe tip.
Q3: What material is the probe tip made of?
A3: The probe tip is molded from Polyphenylene Sulfide (PPS) for high durability.
Q4: Can I mix this probe with older 3300 series components?
A4: Yes, it is electrically and mechanically compatible with non-XL 3300 series 5 mm and 8 mm components.
Q5: What is the recommended gap setting for installation?
A5: The recommended initial gap is approximately 1.27 mm (50 mils), corresponding to -9 VDC.
Q6: How is the cable secured to prevent loosening?
A6: The ClickLoc connector provides a finger-tight, locking connection that clicks when properly secured.
Q7: Does this model require special tools for installation?
A7: No special tools are needed; the SpringLoc terminals and ClickLoc connectors are tool-free.
Q8: What is the expected linear measurement range of this probe?
A8: The linear measurement range is 2.0 mm (80 mils), starting from approximately 0.25 mm from the target.