Technical Specifications
Parameter | Description |
---|---|
Product Model | NMFC02 |
System Type | Net 90 / Infi 90 Process Control System |
Module Type | Multi-Function Controller Module |
Power Supply | 5 VDC, ±15 VDC, 24 VDC |
Power Consumption | Approx. 15 W |
Communication Bus | Module Bus / I/O Expander Bus |
Control Functions | Supports various process control and I/O functions |
Mounting | Pluggable module, hot-swappable |
Cooling | Fan-assisted cooling (IEFAN01/02) |
Operating Temp | 0°C to 55°C |
Storage Humidity | 5% to 90% non-condensing |
Certification | CSA certified for ordinary process control environment |
Dimensions (W×H×D) | 200 × 100 × 30 mm |
Weight | 1.06 kg |
FAQ
Frequently Asked Questions (FAQ)
Q1: What control system is the NMFC02 module designed for?
A1: NMFC02 is designed for use in ABB Bailey’s Net 90 and Infi 90 control systems, handling various process control functions.
Q2: Is the NMFC02 module hot-swappable?
A2: Yes, it can be safely inserted or removed while the system is powered, provided proper procedures are followed by qualified personnel.
Q3: What is the typical power consumption of the NMFC02?
A3: The typical power consumption is approximately 15 watts.
Q4: What are the power supply requirements for NMFC02?
A4: It requires +5 VDC, ±15 VDC, and +24 VDC power supplies.
Q5: Where is the NMFC02 module installed?
A5: It is installed in a module mounting unit such as IEMMU01/02 or power mounting unit IEPMU01/02 depending on the cabinet configuration.
Q6: How does NMFC02 communicate with the system?
A6: It communicates via the Module Bus and I/O Expander Bus with other controllers and I/O modules in the system.
Q7: What are the environmental requirements for NMFC02?
A7: The module must operate in a clean, non-corrosive indoor environment with 0–55°C temperature and up to 90% non-condensing humidity.
Q8: Does the NMFC02 meet any industrial certifications?
A8: Yes, it complies with IEEE-472-1974 surge test standards and is CSA certified for process control environments.