Products Description




Company Information | |||
[email protected] | |||
Mobile | +8613666033393 | ||
+8613666033393 | |||
13666033393 | |||
Add | Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China |
Technical Specifications
Parameter | Specification |
---|---|
Model | 330101-00-32-10-02-05 |
System Type | 3300 XL 8 mm Proximity Transducer System |
Probe Tip Material | Polyphenylene sulfide (PPS) |
Case Material | AISI 303/304 stainless steel |
Cable Type | 75Ω triaxial, FEP insulated (standard), PFA (ETR version) |
Connector Type | Miniature coaxial ClickLoc |
Linear Range | 2 mm (80 mils); from 0.25 mm to 2.3 mm (10 to 90 mils) |
Recommended Gap Setting | -9 Vdc (~1.27 mm / 50 mils) |
Incremental Scale Factor (ISF) | 7.87 V/mm (200 mV/mil) ± 5% (5m or 1m systems) |
DSL Deviation | ±0.025 mm (±1 mil) typical |
Frequency Response | 0 to 10 kHz (+0, -3 dB with up to 305 m of field wiring) |
Operating Temperature (Probe) | -52°C to +177°C (Standard), -52°C to +218°C (ETR probe tip) |
Operating Temperature (Cable) | -52°C to +177°C (Standard), -52°C to +260°C (ETR cable) |
Operating Temperature (Sensor) | -52°C to +100°C |
Storage Temperature (Sensor) | -52°C to +105°C |
Minimum Shaft Diameter | 50.8 mm (2 in); recommended ≥ 76.2 mm (3 in) |
Minimum Target Size | 15.2 mm (0.6 in) diameter |
Minimum Cable Bend Radius | 25.4 mm (1.0 in) |
Sealing (Pressure) | Viton® O-ring; not pressure-tested by default |
Humidity Tolerance | ≤ 3% ASF change after 56 days at 93% RH (IEC 68-2-3 compliant) |
Compliance | API 670 compliant; SIL 2/3; RoHS; CE mark; ATEX/IECEx |
Electrical Input (Sensor) | -17.5 to -26 Vdc, 12 mA max |
Output Resistance | 50 Ω |
Total Length | 1.0 meter |
Weight | 0.323 kg (total system typical) |
FAQ
Frequently Asked Questions (FAQ)
Q1: What is the main application of the 330101-00-32-10-02-05 proximity probe?
A1: It is used primarily for vibration and position measurements in fluid-film bearing machines, and also supports Keyphasor and speed measurements.
Q2: Does this model meet API 670 standards?
A2: Yes, the standard 3300 XL 8 mm 5-meter system fully complies with the API 670 mechanical configuration, accuracy, linear range, and temperature stability standards.
Q3: Is the 330101 probe compatible with non-XL systems?
A3: Yes, it is electrically and physically interchangeable with non-XL 3300 5 mm and 8 mm systems, though performance is limited by the lowest-spec component.
Q4: Can this probe be used in high-temperature environments?
A4: Yes. The standard version supports up to +177°C, and the Extended Temperature Range (ETR) version supports up to +218°C (probe tip) and +260°C (cable).
Q5: What environmental sealing does the probe offer?
A5: The probe features a Viton® O-ring pressure seal but is not pressure-tested before shipment. Applications requiring pressure testing should contact Bently Nevada.
Q6: How should I mount the probe to ensure proper operation?
A6: Maintain minimum probe-to-probe spacing: 40 mm for axial, 38 mm for radial. Mount with proper torque and ensure alignment with shaft centerline.
Q7: Is calibration required before installation?
A7: No. The system components are factory-calibrated and fully interchangeable without the need for bench calibration.
Q8: Can the connectors be installed without tools?
A8: Yes. The ClickLoc connectors are finger-tightened and lock with an audible “click”, requiring no special tools for installation or removal.
Tags
Packing & Delivery
We will use wear-resistant cartons to seal the boxes, and take photos for your confirmation before sealing. We will pack the boxes only after confirmation.
For express delivery, we will use DHL, UPS, TNT, FedEx and EMS.
Please rest assured that we have a deep cooperation with express delivery companies and can ensure that your goods are delivered to you in good condition.