Technical Specifications
Parameter | Specification |
---|---|
Model | MU-TAIH52 |
Description | High Level Analog Input / Smart Transmitter Interface (STI) |
Input Channels | 16 analog input channels |
Input Signal Type | 4–20 mA or 1–5 VDC (configurable) |
Isolation | Galvanically isolated from system and other channels |
Termination Type | Fixed screw terminals |
Communication Interface | Smart Transmitter Interface (STI) |
Redundancy | Supports IOP redundancy |
Mounting Type | Cabinet-mounted, compatible with HPM subsystem |
Power Supply | Supplied via IOP connection |
Dimensions | 137 mm × 51 mm × 151 mm |
Weight | 0.5 kg |
Operating Temperature | 0°C to 60°C |
Storage Temperature | -40°C to 85°C |
Humidity Range | 5% to 95% non-condensing |
Regulatory Compliance | CE compliant, UL listed |
FAQ
Frequently Asked Questions (FAQ)
Q1: What type of signals can the MU-TAIH52 module accept?
A1: The module accepts high-level analog signals, typically 4–20 mA or 1–5 VDC.
Q2: Does the module support smart transmitters?
A2: Yes, it supports smart transmitters via the STI (Smart Transmitter Interface).
Q3: Is the MU-TAIH52 module galvanically isolated?
A3: Yes, it provides galvanic isolation between input channels and the system.
Q4: Can this module be used in a redundant configuration?
A4: Yes, the module supports IOP redundancy for increased system reliability.
Q5: What kind of terminal does it use for wiring?
A5: It uses fixed screw terminals for secure and robust connections.
Q6: What system is the MU-TAIH52 designed to work with?
A6: It is designed for integration into Honeywell’s High-Performance Process Manager (HPM) systems.
Q7: How many input channels does the module support?
A7: It supports 16 analog input channels.
Q8: What are the environmental operating conditions for this module?
A8: Operating temperature is 0°C to 60°C, and humidity range is 5% to 95% non-condensing.