Technical Specifications
Parameter | Specification |
---|---|
Product Model | AIP171-S2 |
Description | Transceiver Control Unit for V net |
Power Supply | Supplied from base unit |
Communication Interface | Optical port for V net |
Installation Location | Mounted in a base unit |
Application Environment | Hazardous area (NI compliant) |
Operating Temperature | 0 to 55°C |
Storage Temperature | -40 to 70°C |
Humidity Range | 5% to 95% RH (non-condensing) |
Certifications | FM NI (Class I, Division 2), ATEX Type “n” |
Explosion Protection Type | Non-Incendive, Type “n”, IECEx compliant |
Mounting Method | Keyed metal cabinet |
Dimensions (W×H×D) | 27.2 × 130 × 176 mm |
Weight | 0.3 kg |
FAQ
Frequently Asked Questions (FAQ)
Q1: What is the primary function of the AIP171-S2 unit?
A1: The AIP171-S2 functions as a transceiver control module for V net, enabling communication over an optical network within safety systems.
Q2: Is the AIP171-S2 suitable for use in hazardous environments?
A2: Yes, it complies with FM (NI), ATEX Type “n”, and IECEx standards for use in Zone 2/Division 2 hazardous areas.
Q3: What kind of cabinet is required for installation in hazardous areas?
A3: A keyed metal cabinet with an IP54 protection rating or higher is required for compliant installation in hazardous areas.
Q4: Does the AIP171-S2 have any special grounding requirements?
A4: Yes, proper grounding must be ensured according to IEC/EN 60079-14 or local regulations to maintain explosion protection compliance.
Q5: Can the AIP171-S2 be used with existing ProSafe-RS systems?
A5: Yes, it is designed to integrate seamlessly with Yokogawa ProSafe-RS safety systems.
Q6: What type of communication does the AIP171-S2 support?
A6: It supports optical communication over Yokogawa’s proprietary V net.
Q7: What precautions should be taken during maintenance?
A7: Maintenance must be done with the power turned off and in a non-hazardous atmosphere. Only qualified personnel should perform maintenance.
Q8: What is the recommended ambient temperature for operation?
A8: The recommended operational temperature range is 0 to 55°C.